TROUBLESHOOTING
ADDRESSING YOUR PROBLEMSROOF LIFT
SINGLE-CAB TRUCK CAMPER: This camper uses a higher capacity rooflift actuator to the other campers, given it has a larger roof. If the roof will not lift, make sure there is power to the camper (i.e. the eFusionBlue is turned and illuminated inside the electrical bay). Ensure the Roof lift button on the black switch panel in the external kitchen area is on and illuminated. Ensure all 4 over-centre roof latches are unlatched correctly. Ensure the roof lift remote control has power. If not, change the batteries and try or use the electric up down button inside the entry door. Sometimes, the remote control disconnects from the control box. You can press and hold the middle button + down arrow at the same time to reset. Then try and raise the roof. If however, the roof is up and wont come down, check the power and buttons are all switched on, try lowing with the entry button and or try resetting the remote – hold the middle button + down arrow at the same time to reset.
ALL OTHER CAMPERS: With this roof lift actuator system, it is used on our Dual-Cab Truck, Dual-Cab Ute, extra-Cab Ute & single-Cab ute camper. If the roof will not lift, make sure there is power to the camper (i.e. the eFusionBlue is turned and illuminated inside the electrical bay). Ensure the Roof lift button on the black switch panel in the external kitchen area is now turned on and illuminated. Ensure all 4 over-centre roof latches are unlactched correctly. Ensure the roof lift remote control has power. If not, change the batteries or use the electric up down button inside the entry door. The most common issue, is this remote and entry door button has a locking safety feature to prevent it going up and down accidentially. You need to hit the up button twice in close proximity to the camper until you hear a beep. Then try raising or lowering the roof after the beep. You must keep the button pressed to keep raising or lowering. Sometimes, the remote control disconnects from the control box. You can press and hold the up button + down arrow at the same time to reset. Then try and raise or lower the roof.
INVERTER & 240V POWER ISSUES
INVERTER & 240v Power: If the air conditioning, hot water system and induction cooktop or anything plugged into a GPO (Power Point) is not getting power, then most likely your inverter is switched off which means no 240v power, particularly if you are still getting 12v power for lighting etc. Unless you have switched it off manually, which is unlikely, then it has been switched off through the Ekrano GX touch screen. To switch it back on, first check the breakers in the 240v switch box have not tripped. This is an important safety step before training to reestablish 240v power because it may not be the inverter, it may be a fault elsewhere. The 4 x 240v breakers are located inside the 240v distributor box in the electrical bay. This is a grey box with a clear window that has PowerSafe written on it. Inspect the breakers to ensure they are all in the up position. If any have tripped, they will be in the down position which means there is a fault. This means the inverter is not disable but rather the 240v power has tripped downstream from the inverter and 240v switch box. Each breaker is labelled as follows: – RCD (Safety switch), HWS (Hot Water System) A/C (Air conditioning) and GPO (General Power Outlets / Power Points). If only one of these is tripped, unless its the RCD then only that circuit will be disabled. If the RCD is tripped, there will be no 240V power until it is reset. Similarly, with any breaker, whether its the hot water system or air conditioning, if its tripped only that device will cease to function. If upon resetting, which can be done by opening the clear window and push the breaker tab back up, it decides to trip again, you have a fault that needs investigation by a qualified electrical professional. If however, it happily stays reset, turn turning the appliance back on. If the appliance trips the breaker when turning the appliance on, there is likely then a fault with the appliance. Either way, you need an electrical professional to professionally diagnose and rectify the fault.
In the event that all breakers are acitve and not tripped, then your inverter is off or has a fault itself. While you are in the electrical bay, check for blown fuses(s). To do this, follow the thick orange cabling (weldflex) from the inverter back to the load distributor (busbar). If the corresponding fuse or fuses (in the case of the 5000W inverter) have blown, you will see a red LED(s) illuminated on the cover. We do not suggest going any further as it would have blown for a reason and needs to be further investigated by a qualified electrical professional.
If the fuses are OK, go to the other side of the camper to check on the Ekrano GX the inverter is turned on. To do this, down the bottom of the screen there is section in grey box that says ‘AC Mode’. This does not mean Air Con or Air Conditioning, it means Alternating Current or 240v power. If it says off, that is likely your problem. The inverter is off so press the screen where it says off until it says on. There are several other modes including inverter only and charger only. It needs to be set to on. Some customers sometimes think the AC means air conditioning and they switch that off and wonder why all 240v power is now disabled.
While the inverter is on but with no load, it will draw about 35 – 40 watts on its own as shown on the Ekrano GX. Sometimes, customers will say everything is off but I am still drawing power. This is the inverter ready to serve 240V power. If you dont need to use the 240v power, perhaps switch the inverter off on the Ekrano GX by pressing the on to off but remember to turn in back on or you will not get 240v power.
INVERTER HARD RESET: Sometimes the inverter can have a fault issue and need to be manually reset. The physical operation of the Victron MultiPlus Inverter is managed by a three-position rocker switch on the unit itself.
Physical Switch Operation is as follows
I (On): This position enables the full function of the unit, including the inverter (converting DC to AC) and the charger (if AC input is present).
O (Off): This is the middle position and turns the inverter and charger function off.
II (Charger Only): This position activates only the battery charger (if AC input is present).
Complete Power Disconnection (Shut Down Procedure)
Switching the unit to ‘O (Off)’ does NOT completely de-power the MultiPlus. Dangerous DC voltage remains present from the battery.
Turn off DC power by pressing the eFusionBlue button ensuring its no longer illuminated.
Switch to Off: Put the physical On/Off/Charger-only switch on the unit to the ‘O (Off)’ position.
Disconnect AC Power: Switch off or disconnect the AC power source connected to the ‘AC in’ terminal (e.g., shore power or generator).
Warning: Always follow safety instructions. Residual voltages may still exist inside the product even after shutdown.
To Turn It Back On
To bring the inverter back into full operation:
Turn On DC Power: Turn on the DC powe by pressing the eFusionBlue button until its illuminated.
Reconnect AC Power (if needed): Apply the AC input power (e.g., shore power or generator).
Switch to On: Put the physical On/Off/Charger-only switch on the unit to the ‘I (On)’ position.
HOT WATER SYSTEM: With the hot water system, there is an added step to ensure power is active to the unit and this is because unit has an isolation button in the entry area of the camper. This is a green switch on a black panel that has the branding of ‘Truma’. This green button needs to be pressed. Once illuminated green, the hot water system should then have power. If not, follow the steps for checking breakers and the inverter being turned on.
NO POWER
NO POWER: If your camper has no power, check the eFusionBlue button is turn on and illuminated. If it is not illuminated or will not turn on, its quite possible your camper batteries are out of power or at a low SOC (State of Charge) and thus the BMS has turned off the entire system to avoid over discharge of the batteries.
RECHARGE: You will need to put charge back into the batteries through either the solar system (rooftop and or the deployable solar panels – if you have purchased them) or from your vehicle via the Anderson Plug connection to the camper’s DC to DC charger. Failing either of these two non-grid charging options, you can plug either mains power (240v grid power) or a generator into the camper’s 15A black receptical. Please follow our plugging into Mains Power Procedures Guide which is available on our website’s Info Page.
SOLAR
NO SOLAR: If the Ekrano GX Touchscreen is telling you there is no solar input in watts (W) registering, there could be a number of possibilities. Firstly, check the solar isolator / breaker has not tripped. If it has, it is generally not advised to turn it back on because it indicates a fault or short circuit with a panel(s), wiring or connections. If you did turn it back on and it trips immediately again, that is certainly the case so leave the breaker tripped or in the down position. You will need a qualified electrical professional to investigate further. This procedure applies to both your rooftop solar and deployable solar.
Alternatively, if the breaker has not tripped and the Victron MPPT is showing flashing lights, follow the wiring back to input on the load distributor (busbar) to see if the corresponding fuse has blown. If so, you will see a red LED illuminated on the cover. We do not suggest going any further as it would have blown for a reason and needs to be further investigated by a qualified electrical professional. If however there is no below fuse, tripped breaker and the MPPT is flashing, there is the possibility of a communication issue between the MPPT and the Ekrano. Given this is hardwired, it is highly unlikely. If you download and install the Victron Connect app, you can connect directly to MPPT as a local device to see if it functioning correctly. Alternatively, in the Ekrano, go to the device list by pressing the OTG Logo. Look for the MPPT. If you cant find it, it may that the MPPT is faulty or has disconnected from the Ekrano if you can see the MPPT in the Victron Connect App.
LOW SOLAR CHARGE: Ensure it’s not night or heavily clouded/shaded. Insufficient solar irradiance is the most straightforward cause. Dirty solar panels is also another cause. They do need to be cleaned on a regular basis.
TAPS, LEAKS, WATER RELATED ISSUES
KITCHEN TAP: To connect or disconnect the kitchen tap / flick mixer, you need to ensure the water pump is turned off. To check this, ensure the water pump button on their black switch panel in the kitchen area is not illuminated. Then connect or disconnect the flexible hoses to the quick connect fittings. Once connected, you can then turn the pump on and use. However, to disconnect, turn the pump off, then release the pressure from the line before disconnecting the hoses by turning the tap / flick mixer on until there is no flow. Then disconnect the quick connect fittings. Next, ensure there is no residual water in the flexible hoses running to the tap / flick mixer and that all water is drained from that line before packing up the drop down sink. Note: – there may be a dribble of water when disconnecting as well as when connecting until full pressure in the line is established which seals the connection.
NO WATER: If you run out of water, you need to check the water guage indicator or digital indicator on the Ekrano GX touchscreen to ensure you have indeed run out. If that is the case, you need to refill the camper water tank using the drinking water (food grade) hose only, to refill the tank through the water refill inlet. Ensure you stay with the hose once its turn on and until the camper water tank is full. You will know once its full as the water will rapidly egress from the refill inlet or breather outlet.
NO HOT WATER: If you have run out of hot water and the hot water system light is still illuminated and the fresh water tank is not empty, then you have used all your hot water and need to wait approximately 20 mins for it to reheat the water in its boiler tank. It is suggested you shower quicker and or wait 20 mins between people having theirs showers.
LOCKS
If a whale lock remains locked after unlocking the central locking, check the other locks are unlocked. If the other locks are unlocked, you need to use a key which you have been provided to unlock that one. If you can hear the lock actuator still clicking on the lock that you cannot open, its likely the pin inside needs adjustment. If you contact us, we can send you a video on how to adjust the pin.
If none of the locks up with the remote, try the second remote you have been provided with. For all locks to fail is highly unlikely, so if there is no unlocking sound, it means the remote(s) are out of battery of the camper batteries are dead. You will need to follow procedures on what happens if there is no power. This does not mean if power is turned off and needs to be turned back on. No the whale locks are wired directly to power and always remain live. In the meantime, you will need to unlock with your keys.